BENCH TOP STATIC NEUTRALIZER 
SNP-01

Air ions are molecules that have lost or gained an electron. Ions are present in normal air but are “stripped” out when an air is subject to filtration and conditioning. They are produced by radioactive emission or by phenomenon called “corona discharge” where a high voltage is applied to sharp point. All air ionization systems work by flooding the atmosphere with positive and negative ion, when ionized air comes in contact with a charge surface; the charge surface attracts ions of the opposite polarity. As a result the static electricity that has build up on products, equipment and surface is neutralized. Typically, air is very insulative with a resistive exceeding 10E15 ohms/meter. By increasing the numbers of ions in the air it is possible to lower the Resistivity of the air to 10E11 ohms/meter, there by making the air more conductive. Conductive air can neutralize the static charge on every surface that it contents. The field from the charged surface attracts ions of the opposite polarity until the charged on the surface is neutralized. The Static neutralizer is portable and uses a small fan to produce airflow. High voltages generated out of the supply line voltage are applied to stainless steel ion emitter points. These points produce intense alternating polarities, ionizing the air instantly in the fan airflow. The Static eliminator-neutralizer is designed for use when handling sensitive electronic components where electrostatic discharge is a problem. The unit can also used where static electricity causes problems such as; attraction of drift to product, misalignment of small parts due to electrostatic “jumping” and undesirable adhesion of plastic films due to electrostatic charge.

Specifications:
Air flow : 1.8 cu m/min
Noise Level : 45dba (at 1 m)
Power Supply : 210V – 250V AC/50Hz
Ionization Voltage : +/- 6KV
Un Balance Voltage : < +/- 100V
Construction : Power coated MS cabinet
Dimensions : 230 x 150 x 110mm
Weight : Apex. 2.9 Kgs
Warranty : One Year


Test Conditions:

1. Test data available using ME268A Charge plate monitor
2. Test Figures are subject to the variation in the atmosphere and Input Ac voltage.
3. Decay Times are found from 1000V to 100V in accordance with EOS/ESD S-3.
4. All data taken using full fan speed 

 

OVER HEAD IONIZER 
OHI-01

Air ions are molecules that have lost or gained an electron. Ions are present in normal air but are “ stripped” out when an air is subject to filtration and conditioning. They are produced by radioactive emission or by phenomenon called “corona discharge” where a high voltage is applied to sharp point. All air ionization systems work by flooding the atmosphere with positive and negative ion, when ionized air comes in contact with a charge surface; the charge surface attracts ions of the opposite polarity. As a result the static electricity that has build up on products, equipment and surface is neutralized. Typically, air is very insulative with a resistive exceeding 10E15 ohms/meter. By increasing the numbers of ions in the air it is possible to lower the Resistivity of the air to 10E11 ohms/meter, there by making the air more conductive. Conductive air can neutralize the static charge on every surface that it contents. The field from the charged surface attracts ions of the opposite polarity until the charged on the surface is neutralized. The Over Head Ionizer is portable and uses a four fan to produce airflow. High voltages generated out of the supply line voltage are applied to stainless steel ion emitter points. These points produce intense alternating polarities, ionizing the air instantly in the fan airflow. The Over Head Ionizer is designed for use when handling sensitive electronic components where electrostatic discharge is a problem. The unit can also used where static electricity causes problems such as; attraction of drift to product, misalignment of small parts due to electrostatic “jumping” and undesirable adhesion of plastic films due to electrostatic charge.

Specifications:

Air flow : 90 CFM
Noise Level : 43 dBA
Power Supply : 210V – 250V AC/50Hz
Ionization Voltage : +/- 6KV
Un Balance Voltage : < +/- 50V
Construction : Power coated MS cabinet
Dimensions : 1220 x 200 x 120mm
Warranty : One Year

Test Conditions:
(P1 – P12) Test data available using ME268A Charge plate monitor 
Test Figures are subject to the variation in the atmosphere and input Ac voltage.
Decay Times are found from 1000V to 100V in accordance with EOS/ESD S-3.
All data taken using full blower speed.
Distance between the Ionizer and charged plate monitor 24 Inches


HORIZONTAL IONIZING AIR BLOWER 
HIAB-01

Air ions are molecules that have lost or gained an electron. Ions are present in normal air but are “ stripped” out when an air is subject to filtration and conditioning. They are produced by radioactive emission or by phenomenon called “corona discharge” where a high voltage is applied to sharp point. All air ionization systems work by flooding the atmosphere with positive and negative ion, when ionized air comes in contact with a charge surface; the charge surface attracts ions of the opposite polarity. As a result the static electricity that has build up on products, equipment and surface is neutralized. Typically, air is very insulative with a resistive exceeding 10E15 ohms/meter. By increasing the numbers of ions in the air it is possible to lower the Resistivity of the air to 10E11 ohms/meter, there by making the air more conductive. Conductive air can neutralize the static charge on every surface that it contents. The field from the charged surface attracts ions of the opposite polarity until the charged on the surface is neutralized. The Horizontal ionizing Air Blower is portable and uses blower to produce airflow. High voltages generated out of the supply line voltage are applied to stainless steel ion emitter points. These points produce intense alternating polarities, ionizing the air instantly in the blower airflow. The Horizontal Ionizing Air Blower is designed for use when handling sensitive electronic components where electrostatic discharge is a problem. The unit can also used where static electricity causes problems such as; attraction of drift to product, misalignment of small parts due to electrostatic “jumping” and undesirable adhesion of plastic films due to electrostatic charge.


Specifications:

Air flow : 170 CFM
Speed : 1700 min-1
Blower width : 320 mm
Power Supply : 210V – 250V AC/50Hz
Ionization Voltage : +/- 6KV
Un Balance Voltage : < +/- 50V
Construction : Power coated MS cabinet
Dimensions : 520 x 300 x 200mm
Weight : Apex. 7.5 Kgs
Warranty : One Year

Test Conditions:

(P1 – P12) Test data available using ME268A Charge plate monitor
Test Figures are subject to the variation in the atmosphere and input Ac voltage.
Decay Times are found from 1000V to 100V in accordance with EOS/ESD S-3.
All data taken using full blower speed


ANALOG STATIC CHARGE METER 
SCM-01

Reliable on-the-spot measurement of static charges has been easier than with the portable SCM-01. Hand-held, yet highly accurate and low drift, the SCM-01 answers three basic questions:

1) Is static present and on what Surfaces, materials or people ?

2) How much static?

3) What is the polarity of the Charge ?

The instrument is ideal for use in such static sensitive environment as electronic component production and assembly areas, clean rooms, computer, medical and R&D Laboratories, surgical rooms, medical device manufacturer, printing pres, packing and production lines, etc.

SPECIFICATIONS:

Measurement Range : +/- 5kV At 2.5 CMS
Measurement Accuracy : +/- 10%
Indication : Analog Dial
Test actuation : Press TO read
Power supply : 9 Volt Battery
Dimensions : 125 x 65 x 35 mm
Weight : 180GMS (With Battery)
Calibration : Recommended every 12 months
Warranty : 12 Months
Optional : Instrument Carry case

 

DIGITAL STATIC CHARGE METER
SCM-02

Reliable on-the-spot measurement of static charges has been easier than with the portable SCM-01. Hand-held, yet highly accurate and low drift, the MPSCM-02 answers three basic questions:

1) Is static present and on what Surfaces, Materials or people ?

2) How much static?

3) What is the polarity of the Charge ?

The instrument is ideal for use in such static sensitive environment as electronic component production and assembly areas, clean rooms, computer, medical and R&D Laboratories, surgical rooms, medical device manufacturer, printing pres, packing and production lines, etc.

SPECIFICATIONS:

Measurement Range : +/- 10kV At 1 Inch
Measurement Accuracy : +/- 10%
Indication : 2 ½ Digit LCD Display
Test actuation : Press TO read
Power supply : 9 Volt Battery
Low battery : warning at 7.0 volts
Calibration : Recommended every 12 months
Dimensions : 135 x 70 x 30mm
Weight : 180 Gms
Warranty : 12 Months

 

 

STATIC LOCATOR 
SCM-03

Reliable on-the-spot measurement of static charges has been easier than with the portable SCM-03. Hand-held, yet highly accurate and low drift, the MPSCM-03 answers three basic questions:

1) Is static present and on what surfaces, materials or people?

2) How much static?

3) What is the polarity of the charge?

The instrument is ideal for use in such static sensitive environment as electronic component production and assembly areas, clean rooms, computer, medical and R&D Laboratories, surgical rooms, medical device manufacturer, printing pres, packing and production lines, etc.

FEATURES:
Light & Hand held model
Boldly visible 2-½ LCD display
Auto Zero setting
UHB LED’s to locate 1” distance
SPECIFICATIONS:
Range : +/-10KV @ 1"
Display : 2-½ digit LCD
Resolution : 100 volts
Accuracy : +/-10%
Power : 9V battery
Low battery : @ 7 Volts
Over scale : ▲ (Indicates over range)
Dimensions : 25 x 60 x 120 mm
Weight : 140gms (with battery)
Calibration : Recommended every 12 months
Warranty : 12 Months

 

 

9V SURFACE RESISTIVITY METER 
SRM-01

This is an ultra wide-range, battery operated, Potable instrument for measuring surface Resistivity of virtually any flat surface. In the circuit industry, products such As packing materials, component storage Bags and trays, work bench surfaces, table and floor mats, conveyor belts, etc., have Resistance value, which need to confirm to Stringent specifications. Moreover, these Values are expected to fall within specified limit. The surface Resistivity meter can play a vital Role in monitoring and checking the Resistivity Characteristic of the above items. It also has unique additional features of surface–to-ground measurement capability Wherein the Resistivity differential between any Surface and any chosen ground can be determined. The surface Resistivity is conveniently indicated by a row of LED’s covering a total of 10 decades from 10E3 to 10E13 ohms/sq.

SPECIFICATIONS:

Measurement Range : 10E3 to 10E13 ohms & ohms/sq
Measurement Accuracy : Half decade
Resolution : One decade
Indication : Visual by different color LED’s
Power supply : 9 Volt Battery
Low battery : Warning at 7.5 V
Dimensions : 135 x 70 x30 mm
Weight : 160 GMS (With Battery)
Calibration : Recommended every 12 months
Warranty : 12 Months
Accessories included : Surface to Ground cord
Optional : Instrument Carry case

 

 

100V SURFACE RESISTIVITY METER 
MPSRM-02

The model SRM-02 surface Resistivity meter is a portable, versatile, instrument designed to accurately measure resistance between two points, surface to ground, and surface Resistivity is accordance with EOS/ESD Association standard S-4.1. The Surface Resistivity meter (included TESTING & MEASURING PROBES) is designed to make all the measurements.

SPECIFICATION:
Measurement Range : <10E3 to >10E12 Ohms or Ohms/sq

Measureme
nt Accuracy : Half decade
Resolution : One decade
Test Voltage : 100V.
Indication : Different Color LED’s

Test actuation : Press To Test
Power supply : 9 Volt Battery

Low battery : Warning at Test Voltage Of 80V
Dimensions : 135 x 70 x 30mm
Weight : App. 200 Gms (With Battery)
Calibration : Recommended every 12 months
Warranty : 12 Months
Accessories included : Surface to Ground cord
Optional : Testing & Measuring Probes


 

DIGITAL SURFACE RESISTIVITY METER 
MPSRM-03

The Surface Resistivity Meter measures both surface resistance and resistance to ground. This is meant for use in evaluating a wide variety of ESD protective materials including tablemats, floor mats, and hard ESD laminates. It measures and displays Surface Resistivity as well as surface to ground and point-to-point resistances. These measurements can be done in the range of <10E3 to >10E12 ohms by using two 2.5-kilo (5lb) heavy electrodes or through internal probes. To check whether surface Resistivity is in accordance with EOS/ESD Association standards S-4.1.

 

 

 

 

 

SPECIFICATIONS:
Measurement Range (LCD) : ≤ 1X10E3 to ≥1X10E12 ohms & ohms/sq
Measurement Range (LED) : < 10E3 to > 10E12 ohms & ohms/sq

Measurement accuracy (LCD) : 0.1 decade
Measurement accuracy (LED) : 0.5 decade

Probe Voltage : 100V +/- 5%
Battery indicator : Green when battery is fully charged

Red for low battery
Test actuation : Press To Read
Power supply : 9V Rech-Battery
Dimensions in mm : 210 x 110 x 40mm

Weight : 500 gms

Calibration : calibration recommended once In 12 months.
Warranty : 12 months from date of Manufacturer
Optional : Testing & measuring probes Esd Audit kit

Accessories : External cable & 12V Charger.

 

TESTING MEASURING PROBES 
SRM03.2

Specification:

Two cylindrical (2.27Kg) 5 Pound metal electrodes shall have a
diameter of 63.5mm (2.5Inches) each having contacts of electrically
conductive materials with a shore-A (IRHD) durometer hardness of

70 (ASTM method D2240-1986). The resistance between the
electrodes shall be less than 1-Kilo ohms when measured at
10Volts or less on metallic surface. These electrodes confirm to ANSI/EOS/ESD-S4.1-1990 Standards.

 


 

WRIST STRAP TESTER 
WST-01

Wrist strap is the first line of defence against electrostatic charges builds up on the human body. it is designed to carry away this charge as soon as it is generated. At the same time wrist strap must remain electrically safe for the user. Thus, it is important to test every wrist strap regularly. In order to protect the sensitive electronic components the maximum wrist strap resistance should not be more than 10 Meg ohms on the other end, the resistance should not be less than 0.75 Meg ohms as protection to the wearer from dangerous level of the voltage and current flow. The wrist strap tester checks these parameters under actual operating conditions with the strap on the wrist. It clearly indicates weather or not the resistance of the wrist strap system including the wearer is at least 0.75 Meg ohms and not more than 10 Meg ohms respectively.

 

SPECIFICATIONS:
Range : Wrist strap 0.75 to 10 Meg ohm
Indications : Pass - GREEN LED
LOW & High fail - RED LED With Audible alarm
Test actuation : By gently pressing metal sensor plate
Accuracy : +/- 10%
Power supply : 9 Volt Battery
Low battery : Warning at 7.0 V

Dimensions : 135 x 70 x 30 mm
Weight : App. 150Gms with battery
Calibration : Recommended every 12 months
Warranty : 12 Months
Optional : Instruction Board, Carry Case & Door Locking System.

 

 

FOOT WEAR TESTER 
FWT-01

Foot wear is the first line of defence against electrostatic charges builds up on the human body. It is designed to carry away this charge as soon as it is generated. At the same time Foot wear must remain electrically safe for the user. Thus, it is important to test every Foot wears regularly. In order to protect the sensitive electronic components the maximum Foot wear resistance should not be more than 100 Meg ohms on the other end, the resistance should not be less than 0.75 Meg ohms as protection to the wearer from dangerous level of the voltage and current flow. The Foot wear tester checks these parameters under actual operating conditions with the Foot wears. It clearly indicates weather or not the resistance of the Foot wears system including the wearer is at least 0.75 Meg ohms and not more than 100 Meg ohms respectively.

SPECIFICATIONS:
Range : Foot Wear 0.75 to 100 Meg ohms
Indications : Pass - GREEN LED
LOW & High fail - RED LED With Audible alarm
Test actuation : By gently pressing metal sensor plate
Accuracy : +/- 10%
Power supply : 9 Volt Battery
Low battery : Warning at 7.0 V
Dimensions : 135 x 70 x 30 mm
Weight : App. 150Gms with battery
Calibration : Recommended every 12 months
Warranty : 12 Months
Optional : Instruction Board, Foot Plate, Carry Case & Door locking System.

 

 

 

WRIST STRAP & FOOT WEAR TESTER 
WSFT-01

Wrist Strap & ESD foot wears are the first line of defence against electrostatic charges build up on the human body.
They are designed to carry away this charge as soon as it is generated. At the same time wrist strap/foot wear must remain electrically safe for the user. Thus, it is important to test every wrist strap / footwear regularly. In or
der to protect the sensitive electronic components the maximum wrist strap resistance should not more than 10 Meg ohms and foot wears resistance should not more than 100 Meg ohms. On the other end, the resistance should not be less than 0.75 Meg ohms as protection to the wearer from dangerous level of the voltage and current flow. The wrist strap and the footwear tester checks these parameters under actual operating conditions with the strap on the wrist or foot wear to the foot. It clearly indicates weather or not the resistance of the wrist strap/foot wear system including the wearer is at least 0.75 Meg ohms and not more than 10/100 Meg ohms respectively. 

SPECIFICATIONS:
Range : Wrist strap 0.75 to 10 Meg ohms
Foot Wear 0.75 to 100 Meg ohms
Range Selection : By slide switch

Indications : Pass - GREEN LED
LOW & High fail - RED LED (With Alarm)
Test actuation : By gently pressing metal sensor plate
Accuracy : +/- 10%
Power supply : 9 Volt Battery
Low battery : Warning at 7.0 V
Dimensions : 135 x 70 x 30 mm
Weight : App. 150Gms with battery
Calibration : Recommended every 12 months
Warranty : 12 Months
Optional : Instruction Board, Foot Plate, Carry Case & Door Locking System.

 

 

WRIST STRAP & DUAL FOOT WEAR TESTER 
WSFT-02

The Wrist strap Cum Dual Footwear tester is a jig type arrangement to test the validity of ESD Wrist strap; Slippons and Shoes and Independent measurement is taken simultaneously of both right, left foot and wrist strap at the same time. Other Footwear testers can only measure two foot at a time, or the combined resistance of both foot. The wrist strap cum Dual Foot Tester reduces the testing time by half, and offers the operator a visual and audible measurement of Pass or fail of both foot and wrist strap before entering the EPA. Operation of Wrist Strap: Connect the wrist strap cord to the instrument with the strap on the wrist; press gently on the metal sensor of the instrument. The instrument comes on automatically when this is done. The operator can check whether the resistance of the wrist strap falls within the acceptable range (0.75 to 10 Meg ohms), This is indicated by green (pass) LED lighting up. Operation of foot wears: Simply stand on the two stainless steel footprints and push the press to test button. The instrument comes on automatically when this is done. The operator can check whether the resistance of the Foot wears falls within the acceptable range of 0.75 to 100 meg ohms, This is indicated by green (pass) LED lighting up.  

Specifications:

Wrist Strap Range : 0.75 to 10 Meg Ohms
Foot Wear Range : 0.75 to 100 Meg ohms
Indications : Pass - GREEN LED

LOW & High fail - RED LED with Alarm
Test actuation : By gently pressing metal sensor plate
Accuracy : +/- 10%
Power supply : 9 Volt Rechargeable Battery

Low battery : Warning at 7.0 V
Dimensions : Instrument: 158x95x 5 mm
Foot plate: 360 x 460 mm
Weight : Instrument (300Gms)/Foot Plate (3.5Kgs)
Calibration : Recommended every 12 months
Warranty : 12 Months
Optional : Door Locking System

 

 

STATIC ALARM 
SA-01

The Static Alarm senses changes in electrostatic fields. The static alarm is ideal for scanning the electrostatic field in critical areas of production and testing of electronic circuit, plastic and textile industries.

SPECIFICATIONS:

Detection method : charge coupling by field Interception
Detection sensitivity : +/- >100V
Range selection : Auto ranging and auto resetting
Indication : Prominent for LED visual Indication with Audible alarm
Power supply : 9V Battery
Dimensions : 135 x 70 x 30mm
Weight : Approximately 135G (with battery)

NOTE: The specifications mentioned in this datasheet are subject to change without prior notice due to our continuous program of product development. Buyer or User shall be responsible for deciding the suitability.

 

 

SINGLE CHORD  WORK STATION MONITOR (for one operator)
WSM-01

The Model WSM-01 has independent circuitry designed to continuously monitor the connections to ESD earth of Wrist strap & Work surface.

WRIST STRAP: This section continuously monitors the wrist strap to detect loss of continuity between operator and monitor. Conditions such as broken coils cords and improper contact with the skin are detected instantly to alert the operator before serious and expensive ESD damage can occur. As there is no resistance return path from the wrist strap, it uses the ‘capacitive AC pulse principle’ to check if the operator is adequately grounded. The wrist strap section is automatically activated when it is plugged in. continuous monitoring reduces the need for periodic checks and also ensures greater security. ESD WORK SURFACE: The work surface is monitored by a DC Resistive principle and a warning is given in case the surface to ground resistance exceeds the safe threshold value of 10 Meg ohms.

ESD WORK SURFACE CONNECTION DIAGRAM:

SPECIFICATIONS:

Pass Threshold : under 4 Meg ohms for wrist strap : Under 10 Meg ohms for MAT
Indication        :        Green LED wrist strap : Pass
                                Red LED wrist strap : Fail
                                Red LED mat : Fail
                                Audible alarm : Flashing Red LED for wrist strap
                                Steady Red LED for MAT
Input power : 12V 500 ma DC
Accuracy : +/-10%
Repeatability : +/-10%
Dimensions : 125 x 65 x 35mm
warranty : One year
Optional : 12V Adopter.

SINGLE CORD WORK STATION MONITOR (for two operator) 
WSM-02

The Model WSM-02 has independent circuitry designed to continuously monitor the connections to ESD earth of two Wrist strap sections & Work surface. 

WRIST STRAP: two-wrist strap sections continuously monitor the wrist strap to detect loss of continuity between operators and monitor. Conditions such as broken coils cords and improper contact with the skin are detected instantly to alert the operator before serious and expensive ESD damage can occur. As there is no resistance return path from the wrist strap, it uses the ‘capacitive AC pulse principle’ to check if the operators is adequately connected to the instrument. The wrist strap sections are automatically activated when it is plugged in. continuous monitoring reduces the need for periodic checks and also ensures greater security. 

 

ESD WORK SURFACE: The work surface is monitored by a DC Resistive principle and a warning is given in case the surface to ground resistance exceeds the safe threshold value of 10 Meg ohms. CONNECTION DIAGRAM: -

PARTS SUPPLIED WITH CONTINUOUS WORK STATION MONITOR
1. Fixing Clamp
2. 18VDC Adopter (Optional)
3. Warranty certificate 

SPECIFICATIONS:

Pass Threshold : under 4 Meg ohms for wrist straps : Under 10 Meg ohms for MAT
Indication        :
Green LED wrist strap : pass
                        Red LED wrist strap : Fail
                        Red LED mat : Fail
                        Audible alarm : Flashing Red LED for wrist strap
                        Steady Red LED For MAT
Input power : 18V 500 ma DC
Accuracy : +/-10%
Repeatability : +/-10%
Dimensions : 130 x 90 x 30 mm
weight : Appx - 300 Grams.
warranty : One year
Calibration : Recommended every 12 Months

 

HUMAN BODY VOLTAGE CHECKER 
SC-01

WHAT IS STATIC ELECTRICITY:
Static electricity is an electrical charge that is at rest, as opposed to electricity in motion or current electricity. Static charges can be generated by either friction or induction.

HOW IS GENERATED:
The most common generation of static charge is the triboelectric charge or the friction electricity developed when rubbing tighter and then separating two masses. For example, when two blocks are rubbed tighter and then separated, a triboelectric charge is developed on each block. The two blocks will have opposite polarities; one will be negatively charged and the other will be positively charged.

STATIC GENERATION FROM THE CARPET: When a person walks across a carpet or tile floor, a triboelectric charge builds up in the body due to the friction between the shoes and the floor material. The more you generate this friction static the greater the voltage potential develops in the body, you are acting as a capacitor. Everyone’s capacitance to hold charges is different. However a sure sign of static presence is hair standing on end or static discharge sparks. Static discharges cab be noticed when you touch an object of lower electrical potential such as a door knob, and a bold of electricity flows from your charged body to the knob. This flows of electricity is actually a result of the stored static charge that is being rapidly discharged to the lower potential object. This discharge that can be felt as well as seen, is commonly referred to as an electrostatic discharge, or “ESD” Human Body Voltage Checker is a new and unique visual method of detecting how much static charge a person is carrying. The unit can be wall mounted outside the ESD protected area to avoid charged persons unknowingly entering, or used by operators to periodically check that they are not creating a charge within the protected area. The meter must always be grounded, to produce an accurate measurement, but more importantly to allow the operator to discharge to a safe handling limit. Touch to test, and watch the LIQUID CRYSTAL DISPLAY indicated between 000 to 1999 Volts of static charge + or – polarity.

SPECIFICATIONS:
Power supply : 9V Dc battery
Accuracy : +/-10%
Resolution : 1 Volt
Low battery indication : low battery set voltage 6.5 volts
Test actuation : touch to test
Dimensions in mm : 135 x 70 x 30 mm
Weight : 165gms (with battery)
Calibration : Recommended once in 12 months

IMPORTANT INSTRUCTIONS:

The instrument must always be connected to ground; not grounding the unit can result in inconsistent results. If the Human body Voltage Checker is not grounded, a charge is retained just as an insulator would retain a charge and therefore the readings are inconsistent. The circuit will only become responsive when you offer a path to ground.

OPERATION:

Personnel before entering the ESD safe area should check for static voltage and discharge to ground through the meter. Place the finger on the ‘touch to test’ metal plate to know the amount of voltage a person is carrying and you can see the amount of charge is gradually goes to ground.

APPLICATION:

1. Human Body Voltage Checker can be used to detect how much static a person is carrying.

2. Will indicate if wrist straps and coil cords are functioning, ground leads, bounding plugs, heel straps, custom floors, Static Spray Coating, etc

 

HUMAN BODY VOLTAGE CHECKER (With Hazard Alarm)

SC-02 WHAT IS STATIC ELECTRICITY: Static electricity is an electrical charge that is at rest, as opposed to electricity in motion or current electricity. Static charges can be generated by either friction or induction. HOW IS GENERATED: The most common generation of static charge is the triboelectric charge or the friction electricity developed when rubbing tighter and then separating two masses. For example, when two blocks are rubbed tighter and then separated, a triboelectric charge is developed on each block. The two blocks will have opposite polarities; one will be negatively charged and the other will be positively charged.

STATIC GENERATION FROM THE CARPET:
When a person walks across a carpet or tile floor, a turboelectric charge builds up in the body due to the friction between the shoes and the floor material. The more you generate this friction static the greater the voltage potential develops in the body, you are acting as a capacitor. Everyone’s capacitance to hold charges is different. However a sure sign of static presence is hair standing on end or static discharge sparks. Static discharges cab is noticed when you touch an object of lower electrical potential such as a doorknob, and a bold of electricity flows from your charged body to the knob. This flows of electricity is actually a result of the stored static charge that is being rapidly discharged to the lower potential object. This discharge that can be felt as well as seen, is commonly referred to as an electrostatic discharge, or “ESD” Human Body Voltage Checker is a new and unique visual method of detecting how much static charge a person is carrying. The unit can be wall mounted outside the ESD protected area to avoid charged persons unknowingly entering, or used by operators to periodically Check that they are not creating a charge within the protected area. It is very simple to use and only requires the personnel under test to touch the plate on the instrument and directly read the charge level on the meter. Apart from the measuring the charge, it can also be used to safely drain away the charges Existing on the body. It has a feature of visual and audible warning when it detects voltage over a certain threshold.

IMPORTANT INSTRUCTIONS:

The instruments must always be connected to ground; not grounding the unit can result in inconsistent results. If the Human Body Voltage Checker is not grounded, a charge is retained just as an insulator would retain a charge and therefore the readings are inconsistent. The circuit will only become responsive when you offer a path to ground.

APPLICATION:

1. Human Body Voltage Checker can be used to detect how much static a person is carrying.

2. Human Body Voltage Checker will audit any potential static generator or dissipater, like. Wrist straps, heel grounders, toe straps, static safe shoes, chairs, floor mats, ground leads, purpose built floors, garments, static sprays, floor finishes, etc....
 

SPECIFICATIONS:
Dimension : 180 X 100 X 45 MM
Weight : 320 Grams (With battery)
Indicating Range : +/- 1999V
Display : 3 ½ Digit LCD Display
Resolution : 1 Volt
Accuracy : 10%
Test Surface : S.S. Plate
Power Supply : 9V Battery
Calibration : Recommended once in 12 months
Warranty : 12 Months
Accessories : Instruction Board with Instrument Fixing Clamp & 1 Meg Ohms Molded Grounding Cord.

FUME ABSORBER 
FA-01

FUME ABSORBER is a portable Fume Extractor incorporating state of- the-art technology. A power fan in the unit, draws the fume onto a special activated - carbon filter, The fact that soldering fumes carry a positive charge is taken advantage of in the design. The filter is given a negative electrostatic charge to improve the efficiency and fume trapping ability.

SPECIFICATIONS:

Power source : 230 V AC
Power consumption : 20 Watts
Fan : Sealed ball - bearing brush less Motor
Air Volume : 1.8 cu m / min
Filter element : Replaceable activated - carbon foam
Filer size : 150 x 200 X 230 MM
Warranty : 12 months

 

 

 

Flexible Arm Illuminated Magnifier  
EV

ESD Safe Version

Although this version looks externally similar to others it has several feature in its surface finishes and internal construction that ensure surface resistivity and surface to ground resistance are kept well within the ESD compatible limit. ESD safe Version recommended in applications that are sensitive to damage by electro-static discharge, such in electronics an explosives industries

 

 

 

 

 

 

 
   
     

 
MARVEL PRODUCTS - 208, Allied Industrial Estate, Mahim, Mumbai 400016 - Phones: 91-22-24468346, 24460198 Fax: 91-22-24455782 email: sales@indiamarvel.com